Minimum Order Quantity | 1 Piece |
Material | Metallic |
Power Supply | Lithium Battery 3V Button Cell |
Type Of Instruments | Hand Held |
Color | Metallic |
Size/Dimension | L 10.4 cm, B 5.3 cm, H 2.1 cm |
Feature | Hold Facility , Auto Off ,Timer , Water Resistant |
Type | Digital |
Battery Required | YES |
Resolution | 0.01 |
Weight | Very Light Weight |
Display | LCD Display |
Usage/Application | Farming, Sugar Mills, Labs |
Brand | Elinco |
Humidity | 0% rH to 100% rH |
Model Name/Number | ELTH - 1 |
I Deal In | New Only |
Accuracy | +-2.5% (from 10% to 90%) |
Country of Origin | Made in India |
Product Weight | Very Light Weight |
Warranty | One Year ( 12 Months ) |
Optional | Probe can be used upward and downward for measuring temperature |
Technical Data |
Series: ELTH |
|
Humidity |
||
Measurement Range: |
0% rH to 100% rH |
|
Accuracy: Humidity |
±2.5% (from 10% to 90%) |
|
Resolution: Humidity |
0.1 or 0.01 (optional) |
|
Temperature |
||
Measurement Range: |
–20°C to 60°C (–40°C to 85°C for short duration) |
|
Accuracy: |
±0.2°C (Typical), ±0.4°C (Maximum) |
|
Resolution: |
0.1 or 0.01 (optional) |
|
Unit of measurement |
ºC / ºF – User selectable |
|
Dew Point (DP) |
Yes |
|
Battery |
Lithium Battery 3V Button Cell |
|
Battery Status / warning |
Yes |
|
Features: |
||
Model |
ELTH-1 |
ELTH-2 |
Hold |
Yes |
Yes |
Min / Max |
No |
Yes |
Power Off Timer |
Fixed Auto Off Timer |
User settable “Auto Off Timer” |
Water Resistant |
Yes |
Yes |
Certificate |
Factory Calibration Certificate |
Minimum Order Quantity | 1 Piece |
Material | Metallic |
Model Name/Number | ELTH - 2 |
Accuracy | +-2.5 % (from 10% to 90%) |
Usage/Application | Industrial |
Temperature Range | - 20 Degree C to 60 Degree C (-40 Degree C to 85 Degree C Short Duration) |
Display | LCD Display |
Color | Metallic |
Dimension | L 10.4 cm, B 5.3 cm, H 2.1 cm |
Humidity | 0% rH to 100% rH |
Item Code | 90258090 |
Features | Hold , Min/Max |
Brand | Elinco |
Battery Included | Yes |
Battery Required | Yes |
Power Supply | Lithium Battery 3V Button Cell |
Product Weight | Very Light Weight |
Resolution | 0.01 |
Size/Dimension | L 10.4 cm, B 5.3 cm, H 2.1 cm |
Type | Digital |
Response Time | Very Fast Response |
Warranty | One Year |
Weight | Very Light Weight |
Country of Origin | Made in India |
Technical Data |
Series: ELTH |
|
Humidity |
||
Measurement Range: |
0% rH to 100% rH |
|
Accuracy: Humidity |
±2.5% (from 10% to 90%) |
|
Resolution: Humidity |
0.1 or 0.01 (optional) |
|
Temperature |
||
Measurement Range: |
–20°C to 60°C (–40°C to 85°C for short duration) |
|
Accuracy: |
±0.2°C (Typical), ±0.4°C (Maximum) |
|
Resolution: |
0.1 or 0.01 (optional) |
|
Unit of measurement |
ºC / ºF – User selectable |
|
Dew Point (DP) |
Yes |
|
Battery |
Lithium Battery 3V Button Cell |
|
Battery Status / warning |
Yes |
|
Features: |
||
Model |
ELTH-1 |
ELTH-2 |
Hold |
Yes |
Yes |
Min / Max |
No |
Yes |
Power Off Timer |
Fixed Auto Off Timer |
User settable “Auto Off Timer” |
Water Resistant |
Yes |
Yes |
Certificate |
Factory Calibration Certificate |
Minimum Order Quantity | 1 Piece |
Material | Metallic |
Model Name/Number | ELTH - 2 |
Color | Metallic |
Brand | Elinco |
Accuracy | +-2.5% (from 10% to 90%) |
Battery Required | YES |
Display | LCD Display |
Feature | Hold , Min/Max |
Humidity | 0% rH to 100% rH |
Power Supply | Lithium Battery 3V Button Cell |
Resolution | 0.1 |
Size/Dimension | L 10.4 cm, B 5.3 cm, H 2.1 cm |
Country of Origin | Made in India |
Technical Data |
Series: ELTH |
|
Humidity |
||
Measurement Range: |
0% rH to 100% rH |
|
Accuracy: Humidity |
±2.5% (from 10% to 90%) |
|
Resolution: Humidity |
0.1 or 0.01 (optional) |
|
Temperature |
||
Measurement Range: |
–20°C to 60°C (–40°C to 85°C for short duration) |
|
Accuracy: |
±0.2°C (Typical), ±0.4°C (Maximum) |
|
Resolution: |
0.1 or 0.01 (optional) |
|
Unit of measurement |
ºC / ºF – User selectable |
|
Dew Point (DP) |
Yes |
|
Battery |
Lithium Battery 3V Button Cell |
|
Battery Status / warning |
Yes |
|
Features: |
||
Model |
ELTH-1 |
ELTH-2 |
Hold |
Yes |
Yes |
Min / Max |
No |
Yes |
Power Off Timer |
Fixed Auto Off Timer |
User settable “Auto Off Timer” |
Water Resistant |
Yes |
Yes |
Certificate |
Factory Calibration Certificate |
Minimum Order Quantity | 1 Unit |
Material | Metallic |
Usage/Application | industrial |
Model Name/Number | ELTH - 2 |
Color | Metallic |
Brand | ELINCO |
Accuracy | +- 2.5% (from 10% to 90%) |
Feature | Hold , Min. Max |
Humidity | 0% rH to 100% rH |
Resolution | 0.01 DegreeC |
Country of Origin | Made in India |
Optional | Probe can be used upward and downward for measuring temperature |
Technical Data |
Series: ELTH |
|
Humidity |
||
Measurement Range: |
0% rH to 100% rH |
|
Accuracy: Humidity |
±2.5% (from 10% to 90%) |
|
Resolution: Humidity |
0.1 or 0.01 (optional) |
|
Temperature |
||
Measurement Range: |
–20°C to 60°C (–40°C to 85°C for short duration) |
|
Accuracy: |
±0.2°C (Typical), ±0.4°C (Maximum) |
|
Resolution: |
0.1 or 0.01 (optional) |
|
Unit of measurement |
ºC / ºF – User selectable |
|
Dew Point (DP) |
Yes |
|
Battery |
Lithium Battery 3V Button Cell |
|
Battery Status / warning |
Yes |
|
Features: |
||
Model |
ELTH-1 |
ELTH-2 |
Hold |
Yes |
Yes |
Min / Max |
No |
Yes |
Power Off Timer |
Fixed Auto Off Timer |
User settable “Auto Off Timer” |
Water Resistant |
Yes |
Yes |
Certificate |
Factory Calibration Certificate |